Electronic Parts Authentication and Screening Purchase of electronic parts from part manufacturers
and its authorized suppliers is the lowest risk step in parts procurement.
However, for various reasons, including part obsolescence, lead time
requirements, or unavailability of parts from authorized sources, parts may be
purchased from unauthorized sources such as independent distributors and
brokers. There is a need for authentication and screening of parts purchased
from such sources to verify their authenticity. CALCE provides component authentication and screening
services through its Test Services and Failure
Analysis Laboratory to verify authenticity of parts. Capabilities: CALCE failure analysis laboratory is equipped with
tools, such as optical microscopy, X-ray microscopy, ESEM/EDS and XRF analyzer,
for providing authentication and screening services. Non-destructive
techniques: Optical microscopy is used to conduct external visual
inspection on parts to verify the attributes of parts such as part markings
(part number, date code, country of citizen marking), part termination quality,
and surface quality. CALCE has optical inspection tools over a broad range
of magnifications, including a a NIKON Stereoscope and ZEISS Axiovert
Microscope. X-ray microscopy is used to conduct internal
inspection on parts to verify the attributes of parts such as die size, and
bond wire alignment. X-ray microscopy is also used to detect anomalies such as
missing bond wires, missing die, or presence of contamination. CALCE houses a state-of-the-art X-ray system capable
of performing 2D and Computed Tomography (CT, 3D) inspection, with a maximum
resolution of 0.3 mm, magnification of up to 10,000X, and a maximum tube
voltage of 160 kV. Scanning Acoustic Microscopy
(SAM) Scanning acoustic microscopy (SAM) is used to detect
anomalies such as popcorn cracking in molding compounds, and interfacial
delamination such as delamination between die and leadframe, that are often
caused due to reclamation of parts from discarded electronics. In recent years
there have been many incidents of counterfeit parts that were found to be
reclaimed parts. CALCE uses a SONIX Scanning Acoustic Microscope to
conduct acoustic microscopy. X-ray
fluorescence spectroscopy (XRF) The X-ray fluorescence spectroscopy is used to detect
poor quality or counterfeit parts by measuring the elemental composition of
materials present in the parts and comparing them with an authentic part. XRF
can be a useful tool to detect counterfeit passives. CALCE conducted an
analysis on customer returned Multi Layer Ceramic Chip (MLCC) capacitors using
X-ray fluorescence spectroscopy. The capacitors were found to be similar to an
authentic part except a missing element in the dielectric layer. The missing element
was identified as Yitrium, which is a costly element. Destructive
techniques:
Scanning Electron Microscopy (SEM) / Energy Dispersive Spectroscopy (EDS) Scanning electron microscopy is an inspection
technique that is conducted on parts after removing the encapsulants
(decapsulation) to verify the elemental composition of a cross-section of the
delidded part. For example, SEM microscopy can be used to verify the elemental
composition of the metallization layers. SEM microscopy can also be used to
verify the elemental composition of the molding compounds or the solder plating
composition on the part termination. Chemical analysis in the E-SEM is
performed using energy dispersive spectroscopy (EDS). CALCE houses a state-of-the-art FEI Quanta
Environmental Scanning Electron Microscope (ESEM) with advanced Energy
Dispersive Spectroscopy (EDS), Digital Imaging, and in-situ Heating/Cooling
capabilities. Material
Characterization Tools
|
|
![]() |
|
Acronyms | Disclaimer | Site Map![]() Copyright © 2011 by CALCE and the University of Maryland, All Rights Reserved |
|